mirror of
https://github.com/Unidata/netcdf-c.git
synced 2024-11-21 03:13:42 +08:00
52 lines
2.4 KiB
Plaintext
52 lines
2.4 KiB
Plaintext
Dear UDUNITS user,
|
|
|
|
Version 2 of the UDUNITS package is now available from the UDUNITS
|
|
homepage at <http://www.unidata.ucar.edu/software/udunits/>.
|
|
|
|
The UDUNITS-2 package differs from the previous UDUNITS package in the
|
|
following ways:
|
|
|
|
Support for non-ASCII characters. The original UDUNITS package only
|
|
supports the ASCII character set. The UDUNITS-2 package supports
|
|
the following character sets: ASCII, ISO 8859-1 (Latin 1), and the
|
|
UTF-8 encoding of ISO 10646 (Unicode). This means that unit string
|
|
specifications like "µ°F·Ω⁻¹" are now supported (your viewer
|
|
must support UTF-8 to display this string correctly).
|
|
|
|
Support for logarithmic units. The unit string specification
|
|
"0.1 lg(re 1 mW)" specifies a deciBel unit with a one milliwatt
|
|
reference level. Meteorologists should note that the unit "dBZ"
|
|
(i.e., "0.1 lg(re um^3)") is now supported.
|
|
|
|
Persistent value converters. It is now possible to obtain a converter
|
|
data-object, which can be used to convert numeric values in one
|
|
unit to numeric values in another, compatible unit. The values can
|
|
be float, double, or one-dimensional arrays of floats or doubles.
|
|
|
|
Improved API. Due to the above changes, it was not possible to keep
|
|
the application programming interface of the original UDUNITS
|
|
package. Beginning with version 2.1.0, however, the package
|
|
contains a thin UDUNITS API to the UDUNITS-2 library, so code
|
|
written to the original API can simply be recompiled and relinked
|
|
against the new package. Because the original UDUNITS API uses the
|
|
"utUnit" data-structure and the UDUNITS-2 API uses pointers to
|
|
"ut_unit" data-structures, a small memory-leak is possible in code
|
|
that creates many units. This leak can be avoided by calling the
|
|
new method utFree(utUnit*) when the unit is no longer needed.
|
|
|
|
XML unit database. The unit database is encoded using human-readable
|
|
XML rather than a custom format. The XML parser included in the
|
|
package supports an <import> element to allow easy and convenient
|
|
customization.
|
|
|
|
One thing that has not changed is that all unit string specifications
|
|
understood by the original UDUNITS package are also understood by the
|
|
new UDUNITS-2 package.
|
|
|
|
Please visit the webpage or email <support-udunits@unidata.ucar.edu> if
|
|
you have questions or comments.
|
|
|
|
Regards,
|
|
Steve Emmerson
|
|
UDUNITS-2 Developer
|