binutils-gdb/gas
Alan Modra ce3ab55fa7 ecoff find_nearest_line and final link leaks
Freeing ecoff_debug_info "pointers to the unswapped symbolic info"
isn't a simple matter, due to differing allocation strategies.  In
_bfd_ecoff_slurp_symbolic_info the pointers are to objalloc memory.
In the ecoff linker they are to separately malloc'd memory.  In gas we
have most (obj-elf) or all (obj-ecoff) into a single malloc'd buffer.

This patch fixes the leaks for binutils and ld, leaving the gas leaks
for another day.  The mips elf backend already had this covered, and
the ecoff backend had a pointer, raw_syments used as a flag, so most
of the patch is moving these around a little so they are accessible
for both ecoff and elf.

include/
	* coff/ecoff.h (struct ecoff_debug_info): Add alloc_syments.
bfd/
	* libecoff.h (struct ecoff_tdata): Delete raw_syments.
	* elfxx-mips.c (free_ecoff_debug): Delete.  Replace uses with
	_bfd_ecoff_free_ecoff_debug_info.
	(_bfd_mips_elf_final_link): Init debug.alloc_syments.
	* ecofflink.c (_bfd_ecoff_free_ecoff_debug_info): New function.
	* ecoff.c (_bfd_ecoff_bfd_free_cached_info): Call
	_bfd_ecoff_free_ecoff_debug_info.
	(_bfd_ecoff_slurp_symbolic_info): Replace uses of raw_syments
	with alloc_syments.
	(ecoff_final_link_debug_accumulate): Likewise.  Use
	_bfd_ecoff_free_ecoff_debug_info.
	(_bfd_ecoff_bfd_copy_private_bfd_data): Set alloc_syments for
	copied output.
	* elf64-alpha.c (elf64_alpha_read_ecoff_info): Use
	_bfd_ecoff_free_ecoff_debug_info.
	* libbfd-in.h (_bfd_ecoff_free_ecoff_debug_info): Declare.
	* libbfd.h: Regenerate.
gas/
	* config/obj-ecoff.c (ecoff_frob_file): Set alloc_syments.
	* config/obj-elf.c (elf_frob_file_after_relocs): Likewise.
2023-06-09 12:56:12 +09:30
..
config ecoff find_nearest_line and final link leaks 2023-06-09 12:56:12 +09:30
doc Support Intel FRED LKGS 2023-05-23 14:43:23 +08:00
po
testsuite MIPS: add MT ASE support for micromips32 2023-06-05 11:14:46 +08:00
.gitignore
acinclude.m4
aclocal.m4
app.c
as.c
as.h
asintl.h
atof-generic.c
bignum.h
bit_fix.h
cgen.c gas: equates of registers 2023-05-12 08:55:48 +02:00
cgen.h
ChangeLog gas: bpf: fix tests for pseudo-c syntax 2023-04-27 20:06:30 +02:00
ChangeLog-0001
ChangeLog-0203
ChangeLog-2004
ChangeLog-2005
ChangeLog-2006
ChangeLog-2007
ChangeLog-2008
ChangeLog-2009
ChangeLog-2010
ChangeLog-2011
ChangeLog-2012
ChangeLog-2013
ChangeLog-2014
ChangeLog-2015
ChangeLog-2016
ChangeLog-2017
ChangeLog-2018
ChangeLog-2019
ChangeLog-2020
ChangeLog-9295
ChangeLog-9697
ChangeLog-9899
codeview.c
codeview.h
compress-debug.c gcc-4.5 build fixes 2023-05-17 11:21:43 +09:30
compress-debug.h
cond.c
config.in
configure MIPS: default r6 if vendor is img 2023-06-05 11:00:14 +08:00
configure.ac MIPS: default r6 if vendor is img 2023-06-05 11:00:14 +08:00
configure.com
configure.tgt
CONTRIBUTORS
COPYING
debug.c
dep-in.sed
depend.c
dw2gencfi.c
dw2gencfi.h
dwarf2dbg.c
dwarf2dbg.h
ecoff.c
ecoff.h
ehopt.c
emul-target.h
emul.h
expr.c gas: invoke md_optimize_expr() also for unary expressions 2023-05-19 09:16:29 +02:00
expr.h gas: equates of registers 2023-05-12 08:55:48 +02:00
flonum-copy.c
flonum-konst.c
flonum-mult.c
flonum.h
frags.c
frags.h
gdbinit.in
gen-sframe.c gas: sframe: fix comment 2023-04-19 14:37:42 -07:00
gen-sframe.h
hash.c
hash.h
input-file.c
input-file.h
input-scrub.c
itbl-lex-wrapper.c
itbl-lex.h
itbl-lex.l
itbl-ops.c
itbl-ops.h
itbl-parse.y
listing.c
listing.h
literal.c
macro.c
macro.h
MAINTAINERS
Makefile.am
Makefile.in
makefile.vms
messages.c
NEWS Support Intel FRED LKGS 2023-05-23 14:43:23 +08:00
obj.h Generated docs and include files 2023-05-03 15:00:05 +09:30
output-file.c
output-file.h
read.c gas: equates of registers 2023-05-12 08:55:48 +02:00
read.h
README
remap.c
sb.c
sb.h
sframe-opt.c
stabs.c
subsegs.c
subsegs.h
symbols.c gas: equates of registers 2023-05-12 08:55:48 +02:00
symbols.h
tc.h
write.c Avoid another -Werror=dangling-pointer 2023-04-26 10:32:07 +09:30
write.h

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

		README for GAS

A number of things have changed since version 1 and the wonderful
world of gas looks very different.  There's still a lot of irrelevant
garbage lying around that will be cleaned up in time.  Documentation
is scarce, as are logs of the changes made since the last gas release.
My apologies, and I'll try to get something useful.

Unpacking and Installation - Summary
====================================

See ../binutils/README.

To build just the assembler, make the target all-gas.

Documentation
=============

The GAS release includes texinfo source for its manual, which can be processed
into `info' or `dvi' forms.

The DVI form is suitable for printing or displaying; the commands for doing
this vary from system to system.  On many systems, `lpr -d' will print a DVI
file.  On others, you may need to run a program such as `dvips' to convert the
DVI file into a form your system can print.

If you wish to build the DVI file, you will need to have TeX installed on your
system.  You can rebuild it by typing:

	cd gas/doc
	make as.dvi

The Info form is viewable with the GNU Emacs `info' subsystem, or the
stand-alone `info' program, available as part of the GNU Texinfo distribution.
To build the info files, you will need the `makeinfo' program.  Type:

	cd gas/doc
	make info

Specifying names for hosts and targets
======================================

   The specifications used for hosts and targets in the `configure'
script are based on a three-part naming scheme, but some short
predefined aliases are also supported.  The full naming scheme encodes
three pieces of information in the following pattern:

     ARCHITECTURE-VENDOR-OS

   For example, you can use the alias `sun4' as a HOST argument or in a
`--target=TARGET' option.  The equivalent full name is
`sparc-sun-sunos4'.

   The `configure' script accompanying GAS does not provide any query
facility to list all supported host and target names or aliases.
`configure' calls the Bourne shell script `config.sub' to map
abbreviations to full names; you can read the script, if you wish, or
you can use it to test your guesses on abbreviations--for example:

     % sh config.sub i386v
     i386-unknown-sysv
     % sh config.sub i786v
     Invalid configuration `i786v': machine `i786v' not recognized


`configure' options
===================

   Here is a summary of the `configure' options and arguments that are
most often useful for building GAS.  `configure' also has several other
options not listed here.

     configure [--help]
               [--prefix=DIR]
               [--srcdir=PATH]
               [--host=HOST]
               [--target=TARGET]
               [--with-OPTION]
               [--enable-OPTION]

You may introduce options with a single `-' rather than `--' if you
prefer; but you may abbreviate option names if you use `--'.

`--help'
     Print a summary of the options to `configure', and exit.

`-prefix=DIR'
     Configure the source to install programs and files under directory
     `DIR'.

`--srcdir=PATH'
     Look for the package's source code in directory DIR.  Usually
     `configure' can determine that directory automatically.

`--host=HOST'
     Configure GAS to run on the specified HOST.  Normally the
     configure script can figure this out automatically.

     There is no convenient way to generate a list of all available
     hosts.

`--target=TARGET'
     Configure GAS for cross-assembling programs for the specified
     TARGET.  Without this option, GAS is configured to assemble .o files
     that run on the same machine (HOST) as GAS itself.

     There is no convenient way to generate a list of all available
     targets.

`--enable-OPTION'
     These flags tell the program or library being configured to
     configure itself differently from the default for the specified
     host/target combination.  See below for a list of `--enable'
     options recognized in the gas distribution.

`configure' accepts other options, for compatibility with configuring
other GNU tools recursively; but these are the only options that affect
GAS or its supporting libraries.

The `--enable' options recognized by software in the gas distribution are:

`--enable-targets=...'
     This causes one or more specified configurations to be added to those for
     which BFD support is compiled.  Currently gas cannot use any format other
     than its compiled-in default, so this option is not very useful.

`--enable-bfd-assembler'
     This causes the assembler to use the new code being merged into it to use
     BFD data structures internally, and use BFD for writing object files.
     For most targets, this isn't supported yet.  For most targets where it has
     been done, it's already the default.  So generally you won't need to use
     this option.

Compiler Support Hacks
======================

On a few targets, the assembler has been modified to support a feature
that is potentially useful when assembling compiler output, but which
may confuse assembly language programmers.  If assembler encounters a
.word pseudo-op of the form symbol1-symbol2 (the difference of two
symbols), and the difference of those two symbols will not fit in 16
bits, the assembler will create a branch around a long jump to
symbol1, and insert this into the output directly before the next
label: The .word will (instead of containing garbage, or giving an
error message) contain (the address of the long jump)-symbol2.  This
allows the assembler to assemble jump tables that jump to locations
very far away into code that works properly.  If the next label is
more than 32K away from the .word, you lose (silently); RMS claims
this will never happen.  If the -K option is given, you will get a
warning message when this happens.


REPORTING BUGS IN GAS
=====================

Bugs in gas should be reported to:

   https://sourceware.org/bugzilla/

See ../binutils/README for what we need in a bug report.

Copyright (C) 2012-2023 Free Software Foundation, Inc.

Copying and distribution of this file, with or without modification,
are permitted in any medium without royalty provided the copyright
notice and this notice are preserved.