binutils-gdb/ld/testsuite/ld-i386/no-plt-check1a.S

43 lines
887 B
ArmAsm
Raw Normal View History

i386: Test external function reference without PLT To call an external function, the direct branch to the PLT entry can be replaced by an indirect branch via the GOT slot, which is similar to the first instruction in the PLT slot. Instead using the PLT slot as function address, the function address is retrieved from the GOT slot. The R_386_GOT32X relocation can be used to compute the address of the symbol’s GOT entry without base register when PIC is disabled. In non-PIC executable, call/jmp *func@GOT should be used for indirect branch via the GOT slot and movl func@GOT, %eax should be used to load function address. Unlike PIC case, no register is needed to access GOT. If linker determines the function is defined locally, it converts indirect branch via the GOT slot to direct branch with a nop prefix and converts load via the GOT slot to load immediate or lea. * testsuite/ld-i386/libno-plt-1b.dd: New file. * testsuite/ld-i386/libno-plt-1b.rd: Likewise. * testsuite/ld-i386/no-plt-1a.dd: Likewise. * testsuite/ld-i386/no-plt-1a.rd: Likewise. * testsuite/ld-i386/no-plt-1b.dd: Likewise. * testsuite/ld-i386/no-plt-1b.rd: Likewise. * testsuite/ld-i386/no-plt-1c.dd: Likewise. * testsuite/ld-i386/no-plt-1c.rd: Likewise. * testsuite/ld-i386/no-plt-1d.dd: Likewise. * testsuite/ld-i386/no-plt-1d.rd: Likewise. * testsuite/ld-i386/no-plt-1e.dd: Likewise. * testsuite/ld-i386/no-plt-1e.rd: Likewise. * testsuite/ld-i386/no-plt-1f.dd: Likewise. * testsuite/ld-i386/no-plt-1f.rd: Likewise. * testsuite/ld-i386/no-plt-1g.dd: Likewise. * testsuite/ld-i386/no-plt-1g.rd: Likewise. * testsuite/ld-i386/no-plt-1h.dd: Likewise. * testsuite/ld-i386/no-plt-1h.rd: Likewise. * testsuite/ld-i386/no-plt-1i.dd: Likewise. * testsuite/ld-i386/no-plt-1i.rd: Likewise. * testsuite/ld-i386/no-plt-1j.dd: Likewise. * testsuite/ld-i386/no-plt-1j.rd: Likewise. * testsuite/ld-i386/no-plt-check1a.S: Likewise. * testsuite/ld-i386/no-plt-check1b.S: Likewise. * testsuite/ld-i386/no-plt-extern1a.S: Likewise. * testsuite/ld-i386/no-plt-extern1b.S: Likewise. * testsuite/ld-i386/no-plt-func1.c: Likewise. * testsuite/ld-i386/no-plt-main1.c: Likewise. * testsuite/ld-i386/no-plt.exp: Likewise.
2016-06-09 03:41:50 +08:00
.section .rodata.str1.1,"aMS",@progbits,1
.LC0:
.string "PASS"
.text
.p2align 4,,15
.globl check
.type check, @function
check:
pushl %ebx
call __x86.get_pc_thunk.bx
addl $_GLOBAL_OFFSET_TABLE_, %ebx
subl $8, %esp
call *get_func@GOT(%ebx)
cmpl func@GOT(%ebx), %eax
jne .L3
movl func_p@GOT(%ebx), %edx
cmpl %eax, (%edx)
jne .L3
i386: Test external function reference without PLT To call an external function, the direct branch to the PLT entry can be replaced by an indirect branch via the GOT slot, which is similar to the first instruction in the PLT slot. Instead using the PLT slot as function address, the function address is retrieved from the GOT slot. The R_386_GOT32X relocation can be used to compute the address of the symbol’s GOT entry without base register when PIC is disabled. In non-PIC executable, call/jmp *func@GOT should be used for indirect branch via the GOT slot and movl func@GOT, %eax should be used to load function address. Unlike PIC case, no register is needed to access GOT. If linker determines the function is defined locally, it converts indirect branch via the GOT slot to direct branch with a nop prefix and converts load via the GOT slot to load immediate or lea. * testsuite/ld-i386/libno-plt-1b.dd: New file. * testsuite/ld-i386/libno-plt-1b.rd: Likewise. * testsuite/ld-i386/no-plt-1a.dd: Likewise. * testsuite/ld-i386/no-plt-1a.rd: Likewise. * testsuite/ld-i386/no-plt-1b.dd: Likewise. * testsuite/ld-i386/no-plt-1b.rd: Likewise. * testsuite/ld-i386/no-plt-1c.dd: Likewise. * testsuite/ld-i386/no-plt-1c.rd: Likewise. * testsuite/ld-i386/no-plt-1d.dd: Likewise. * testsuite/ld-i386/no-plt-1d.rd: Likewise. * testsuite/ld-i386/no-plt-1e.dd: Likewise. * testsuite/ld-i386/no-plt-1e.rd: Likewise. * testsuite/ld-i386/no-plt-1f.dd: Likewise. * testsuite/ld-i386/no-plt-1f.rd: Likewise. * testsuite/ld-i386/no-plt-1g.dd: Likewise. * testsuite/ld-i386/no-plt-1g.rd: Likewise. * testsuite/ld-i386/no-plt-1h.dd: Likewise. * testsuite/ld-i386/no-plt-1h.rd: Likewise. * testsuite/ld-i386/no-plt-1i.dd: Likewise. * testsuite/ld-i386/no-plt-1i.rd: Likewise. * testsuite/ld-i386/no-plt-1j.dd: Likewise. * testsuite/ld-i386/no-plt-1j.rd: Likewise. * testsuite/ld-i386/no-plt-check1a.S: Likewise. * testsuite/ld-i386/no-plt-check1b.S: Likewise. * testsuite/ld-i386/no-plt-extern1a.S: Likewise. * testsuite/ld-i386/no-plt-extern1b.S: Likewise. * testsuite/ld-i386/no-plt-func1.c: Likewise. * testsuite/ld-i386/no-plt-main1.c: Likewise. * testsuite/ld-i386/no-plt.exp: Likewise.
2016-06-09 03:41:50 +08:00
call *func@GOT(%ebx)
cmpl $305419896, %eax
jne .L3
call *call_func@GOT(%ebx)
cmpl $305419896, %eax
jne .L3
leal .LC0@GOTOFF(%ebx), %eax
subl $12, %esp
pushl %eax
call *puts@GOT(%ebx)
addl $24, %esp
popl %ebx
ret
.L3:
call *abort@GOT(%ebx)
.size check, .-check
.section .text.__x86.get_pc_thunk.bx,"axG",@progbits,__x86.get_pc_thunk.bx,comdat
.globl __x86.get_pc_thunk.bx
.hidden __x86.get_pc_thunk.bx
.type __x86.get_pc_thunk.bx, @function
__x86.get_pc_thunk.bx:
movl (%esp), %ebx
ret
.section .note.GNU-stack,"",@progbits